Apatent application was made in 1981 for the earth shattering invention of "the original – LUX ELEMENTS® hard foam support ELEMENT".
The construction panel for walls and floors LUX ELEMENTS®-ELEMENT
Construction panel for underfloor heating LUX ELEMENTS®-FLOOR
The installation cladding LUX ELEMENTS®-TEC
Bath surrounds LUX ELEMENTS®-TOP
The washstands LUX ELEMENTS®-LAVADO
Point drainage LUX ELEMENTS TUB®
Linear drainage LUX ELEMENTS TUB-LINE®
Modular room constructions LUX ELEMENTS®-MODUL-ROOM
Individual room constructions LUX ELEMENTS®-CONCEPT
Individual relaxation and distraction LUX ELEMENTS®-RELAX
The decorative elements LUX ELEMENTS®-DECO
The tried and tested accessories are fully harmonised for processing ELEMENT. Specially developed adhesives and mortars, sealing tapes, mounting angles and plugs ensure problem-free processing.
Fastening set and dowels LUX ELEMENTS®-FIX
Technical fixtures, Heating, Lighting and Sound LUX ELEMENTS®-ADD
Adhesives LUX ELEMENTS COL®
Sealing filler and sealing tapes LUX ELEMENTS®-DRY
Reinforce LUX ELEMENTS ARM®
Mounting aids LUX ELEMENTS MONT®
LUX ELEMENTS®-...-PLUS Individual, special manufacture for each product group
In addition to standard products, also individually tailored and specially manufactured products are available for the products groups listed under the designation ‘PLUS‘.
Sizes, shapes, thicknesses etc., that deviate from standard features can be inquired from LUX ELEMENTS. After successful verification of implementation possibility at LUX ELEMENTS an appropriate offer will be prepared. Once an order is placed, it will be manufactured and delivered accordingly.
Overview of All Issues
LUX ELEMENTS GmbH & CO KGAn der Schusterinsel 7D - 51379 Leverkusen-OpladenTelefon +49 (0) 21 71/ 72 12 - 0Telefax +49 (0) 21 71/ 72 12 20
Practical instructions
Application areas
Construction & design
Practical examples
Installation video
The bathtub is positioned and aligned by means of the tub legs, and the connections are professionally mounted.
Wall fittings are required for the installation of the head and side claddings (each approx. 50 x 50 x 500 mm) and fittings for the shelf element, cut from residual material.
The auxiliary end stop for mounting the head element has to be installed first.
For cladding we recommend LUX ELEMENTS®-ELEMENT-EL 30 (50). Take into consideration the thickness of the elements and the added measurement of the tiling when positioning the wall fittings. Depending on the tile thickness, the fitting has to be set back approx. 45 mm (65 mm) from the bath tub edge.
Mark the position of the wall fitting with a vertical line. Markings for drill holes, centre of end stop, top and bottom.
Drill two holes for each wall fitting using an 8 mm drill. Hold the wall fitting in position and hammer in the hammer fix plugs FIX-FID.
Cut the head element with a saw, setting it back from the bath tub edge to allow for the element and tile thickness.
TIP: To facilitate the later installation (see Fig. 9), make handle notches in the lower area.
Apply the adhesive COL-MK to the face end of the wall fitting and the top edge of the head element.
Push the head element firmly under the bath tub edge and against the end stop.
Screw two screw plugs FIX-SD 80 into the wall fitting through the head element.
TIP: Pre-pierce dowel holes using a cross slot screwdriver
Sketch of corner detail.
Detailed sketch, rack: Cut the side element to size using a saw. While doing so, make the notches in the shelf area according to the sketch and in the lower area for easier installation.
Apply COL-MK to the face end of the wall fitting and the head element as well as to the top edge of the side element.
Install the wall fitting for the longitudinal element and the fittings for the shelf element as previously described. For this, again take into account the thickness of the element and the added tile measurement (see Fig. 4)!
Push the side element firmly under the bath tub edge and against the wall fitting and the head element. Then additionally connect the cladding elements and the wall fitting using two FIX-SD 80 screw plugs. TIP: Pre-pierce dowel holes using a cross slot screwdriver
Saw the shelf element to size, apply COL-MK to the upper edge of the shelving fittings. Then position the shelf and push down firmly onto the shelving fittings and the side element.